أسئلة يتكرر طرحها عن مضخات التفريغ

أسئلة يتكرر طرحها عن مضخات التفريغ

أسئلة يتكرر طرحها عن مضخات التفريغ 1. مضخة التفريغ الخاصة بي تعمل ولكن لا يمكنني الفراغ ، فلماذا لا؟ الموصل بين عمود المضخة وعمود المحرك إما تالف أو زلق. تأكد من إحكام البراغي المضبوطة على اللوح ذي العمودين. 2. ما سبب أهمية تغيير الزيت في مضخة التفريغ الخاصة بي؟ يعمل الزيت المناسب كخلاط في مضخة […]

پرسش های متداول در باره پمپ وکیوم

پرسش های متداول در باره پمپ وکیوم

1. پمپ خلا (وکیوم) من کار می کند ، اما نمی توانم خلا بگیرم وکیوم نم کند چرا؟ اتصال دهنده بین شافت پمپ و شافت موتور یا خراب است یا می لغزد. اطمینان حاصل کنید که پیچ های تنظیم شده روی صفحه دو شافت محکم هستند. 2. چرا تعویض روغن در پمپ خلا (وکیوم)من اینقدر […]

Why do I need to check the oil level when the pump is running?

Why do I need to check the oil level when the pump is running?

Why do I need to check the oil level when the pump is running? The reason for this is that if the vacuum is not broken before pumps are shut down the oil in the cover will seek the vacuum still in the cartridge and intake chamber. Then the oil level will drop in the […]

How low of a vacuum should we pull on a system?

How low of a vacuum should we pull on a system?

How low of a vacuum should we pull on a system? JB recommends that a system be pulled to at least 250 microns and held at least five minutes. On any polyester oils in a system, it is recommended to pull a much lower vacuum as moisture is very difficult to remove even with heat […]

Can I mount my micron gauge onto the vacuum pump?

Can I mount my micron gauge onto the vacuum pump?

Can I mount my micron gauge onto the vacuum pump? It is not recommended to do so as you are reading what the pump is doing and not what the pump is doing to the system (see DV-29). It is suggested that you tee off on the suction side of the system and mount the […]

I have been using my low side gauge to pull a vacuum, is this wrong?

I have been using my low side gauge to pull a vacuum, is this wrong?

I have been using my low side gauge to pull a vacuum, is this wrong? YES. The low side gauge knows only atmospheric pressure and cannot sense moisture or non-condensables. A micron gauge is a heat sensing device that not only reads atmospheric pressure, but also measures the gases created by the vacuum pump as […]

My vacuum pump runs, but I cannot get a vacuum.

My vacuum pump runs, but I cannot get a vacuum.

My vacuum pump runs, but I cannot get a vacuum. The coupler between the shaft of the pump and the shaft of the motor is either broken or slipping. Make sure the set screws are tight on the flats of the two shafts.

Oil changing and dust removal – the essentials of vacuum pump care

Oil changing and dust removal – the essentials of vacuum pump care

Oil changing and dust removal – the essentials of vacuum pump care While there are dry running vacuum pumps that do not require any oil, composites industry vacuum pumps are typically of the oil flooded rotary vane type. The reason the composites industry uses oil flooded pumps is because affordable oil-free vacuum pumps are usually […]